The Leading Online Sanitary industry Exhibition Worldwide
English
products
Position:Home > Products > WIKA Instrument, LP
Pressure calibrator CPH6000

33

0

0

Contact supplier

Product Description

Product Catalogues

Product Videos

Applications of the pressure calibrator
Calibration service companies/service industry
Maintenance facilities
Measurement and control laboratories
Quality assurance

Special Features of the pressure calibrator
Digital indicator with easily interchangeable reference pressure sensors (sensor can also be attached externally)
Measuring ranges from 0 ... 250 mbar to 0 ... 8,000 bar (0 ... 4 psi to 0 ... 116,000 psi)
Accuracy: 0.025 % (incl. calibration certificate)
Calibration and pressure-switch test functions
Software and complete service cases (incl. pumps) available

Description of the pressure calibrator
Handling
For a solution that always matches the application, there are many pressure sensors to choose from, with accuracies of up to 0.025 % and measuring ranges up to 8,000 bar (116,000 psi), which can be interchanged quickly and without tools. In addition to being fixed to the pressure calibrator, the reference pressure sensor can, optionally, be used externally via an approx. 1.2 m (4 ft) long connecting cable. If the reference pressure sensor on the instrument is changed, then the digital indicator will recognise the new measuring range and so this saves the operator from having to configure it via the menu.

Functionality
In the setup menu there are 3 operating modes to choose from: MEASURING, CALIBRATION and PRESSURE SWITCHTEST. In the CALIBRATION and PRESSURE SWITCHTEST modes, a menu assistant supports the user during each operation and records, for example, the calibration data from several calibrations or automatically calculates the switch hysteresis. To power the test item and to read its measurement signals, there are electrical inputs and outputs which are protected from adverse conditions in the field by captive protection caps.

Software
For the evaluation and documentation of the calibration data stored in the pressure calibrator CPH6000, WIKA-CAL calibration software is available. Using this software, the data is automatically transferred into a printable calibration certificate. Furthermore, WIKA-CAL also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. For data transfer, an RS-232 and a USB interface are available.

Complete test and service cases
For maintenance and service applications of the pressure calibrator, various service case systems are available. These include service cases with or without pressure generation, charger, test-cable set, adapter, etc.

Certified accuracy
For each reference pressure sensor, the accuracy is certified by a factory calibration certificate which accompanies the instrument. On request, we can provide a DKD/DAkkS calibration certificate for the pressure calibrator.

  • OI_CPH6000_en_de_29353.pdf
    5259 KB
    United States
  • DS_CT1501_en_co_1070.pdf
    2549 KB
    United States
All Products
Other
Log in
New to GM industry Sign up
By signing up,you agree to our terms of use, privacy policy,and cookie policy
have an account? Log in
The Leading Online Sanitary industry Exhibition Worldwide